⚡ US, UK & Australian Standards (Imperial & Metric)

Tile & Grout Calculator (Backsplashes, Floors & Showers)

Calculate ceramic, porcelain, and subway tile quantities, thinset mortar bags, and grout powder requirements.

Tile & Grout Estimator

Universal calculator for tile units, box cartons, pattern waste, and grout powder bags.

Quick:
Quick:
Individual Tiles
1056tiles

Covers 132 sq ft w/ +10% waste

Tile Cartons / Boxes
11boxes

Based on 12.5 sq ft per carton

Grout Powder
22lbs

~3 of 10lb carton or 1 of 25lb bag

Recommended Grout
Unsanded Grout

Protects glossy glaze from scratching

Disclaimer: Calculations provided are estimates for preliminary material planning only. Actual yields vary based on subgrade compaction, site grading, waste, and local trade practices. QuickRenoTools assumes no liability for material shortages, structural failures, code non-compliance, vehicle overloads, or jobsite injuries. Verify all structural spans, retaining wall heights, and concrete mix designs with a licensed engineer, certified contractor, or local building authority prior to purchase and construction. Legal Disclaimer

Pre-Calculated Quick Reference

Tile & Grout Project Materials Cheat Sheet

Quick reference table for backsplashes, shower surrounds, and bathroom floors with 10% cutting waste included.

Swipe table horizontally to see all columns →
Project AreaTile Units (+10% Waste)Carton Boxes (12.5 sq ft / 1.2m²)Thinset Mortar (50lb / 20kg Bags)Grout Powder Bags
Kitchen Backsplash (30 sq ft / 2.8m²)264 subway (274 @ 75×150)3 boxes (3 @ 1.2m²)1 bag (50lb / 20kg)1 box (10 lb / 5kg)
Small Bathroom Floor (40 sq ft / 3.7m²)44 tiles (46 @ 300×300)4 boxes (4 @ 1.2m²)1 bag (50lb / 20kg)1 box (10 lb / 5kg)
Shower Walls (80 sq ft / 7.4m²)704 subway (730 @ 75×150)7 boxes (7 @ 1.2m²)2 bags (50lb / 20kg)1 bag (25 lb) / 2 boxes (10 lb)
Master Bath Floor (120 sq ft / 11.1m²)66 tiles (68 @ 300×600)11 boxes (10 @ 1.2m²)2 bags (50lb / 20kg)1 box (10 lb / 5kg)
Kitchen & Dining (250 sq ft / 23.2m²)138 tiles (142 @ 300×600)22 boxes (21 @ 1.2m²)4 bags (50lb / 20kg)2 bags (25 lb / 20kg)
Values based on standard grid installation (+10% cutting waste), 1/8" (3mm) grout joints, and 12.5 sq ft (1.2 m²) per carton box.
1 US box = 12.5 sq ft | 1 Metric box = 1.2 m² | 1 thinset bag = 50 lb (covers ~65 sq ft) / 20 kg (covers ~6 m²) | Grout: 1 bag = 25 lb (10 kg) or 10 lb box
⚖️ Construction Liability & Code Notice

Disclaimer: Calculations provided are estimates for preliminary material planning only. Actual yields vary based on subgrade compaction, site grading, waste, and local trade practices. QuickRenoTools assumes no liability for material shortages, structural failures, code non-compliance, vehicle overloads, or jobsite injuries. Verify all structural spans, retaining wall heights, and concrete mix designs with a licensed engineer, certified contractor, or local building authority prior to purchase and construction.

Complete Project Checklist

Related Tools for This Project

Building this project? Don't forget your sub-base gravel, reinforcement steel, or finishing supplies:

— GOOD TO KNOW —

Frequently Asked Questions: Tile & Grout Calculator (Backsplashes, Floors & Showers)

Common questions about bag calculations, ordering bulk vs bags, and trade standards.

How much tile cutting waste should I factor in?

Add 10% waste for standard straight grid or 1/3-offset subway tile layouts. Increase to 15% to 20% for herringbone, diagonal (diamond), chevron patterns, or rooms with numerous niches and pipes.

How many square feet of tile are in a standard box?

Most manufacturer tile cartons contain 10 to 15 square feet of tile, depending on tile thickness and size. Check the packaging label, and always order by total required square footage plus waste.

Sanded vs unsanded grout: which should I use?

Use unsanded grout for joint widths 1/8 inch (3 mm) or narrower, and on scratch-sensitive tiles like polished marble. Use sanded grout (or modern polymer-modified grout) for joints 1/8" to 1/2" wide to prevent joint shrinkage and cracking.

How much grout powder do I need for a tiling project?

A standard 25 lb bag of sanded grout covers approximately 100 to 200 square feet with 12×12 or 12×24 tiles and 1/8" joints. Smaller mosaic or subway tiles have vastly more joint lines and require double the grout volume.

How wide should tile grout lines be?

Subway tiles typically use 1/16" or 1/8" joints for a clean classic look. Floor tiles typically use 1/8" to 3/16". Rectified porcelain tiles (with laser-cut 90-degree factory edges) can be spaced at a razor-thin 1/16" joint.

Do I need to seal tile grout after installation?

Yes. Standard cement-based grout is porous and will absorb water, mildew, and stains. Apply a penetrating fluoropolymer grout sealer 72 hours after grouting. Premixed epoxy or urethane grouts are non-porous and do not require sealing.

Can you tile directly over existing tile?

Yes, provided the existing tile floor is structurally sound, crack-free, completely level, and degreased. Scuff the surface with 80-grit sandpaper and apply a specialized bonding primer (such as Eco Prim Grip) before setting new mortar.

What size notched trowel should I use for tiling?

Use a 1/4" × 1/4" square notch trowel for standard 3×6 subway or 8×8 tiles. For large format tiles (any tile with one side longer than 15 inches, such as 12×24), use a 1/2" × 1/2" square notch or 1/2" euro notch trowel and back-butter each tile.

How many subway tiles (3x6 inch) are in one square foot?

Each 3" × 6" subway tile is 18 square inches. Dividing 144 by 18 gives exactly 8 tiles per square foot. With standard 10% waste, order 8.8 tiles per square foot.

What is the difference between ceramic and porcelain tile?

Porcelain is fired at higher temperatures from denser kaolin clay, absorbing less than 0.5% water (impervious), making it frost-proof and ideal for wet bathrooms, heavy traffic floors, and outdoor patios. Ceramic tile is softer, easier to cut, and best for dry wall backsplashes.

⚖️

Construction Liability & Engineering Disclaimer

Essential legal notices, engineering thresholds, and safety limits

Disclaimer: Calculations provided are estimates for preliminary material planning only. Actual yields vary based on subgrade compaction, site grading, waste, and local trade practices. QuickRenoTools assumes no liability for material shortages, structural failures, code non-compliance, vehicle overloads, or jobsite injuries. Verify all structural spans, retaining wall heights, and concrete mix designs with a licensed engineer, certified contractor, or local building authority prior to purchase and construction.

1. Engineering Certification Thresholds

Building materials carry severe physical and financial liability. Certain project dimensions exceed standard residential rules of thumb and legally mandate certified structural engineering:

  • Retaining Walls: Walls exceeding 3 to 4 ft (0.9 to 1.2 m) require stamped structural engineering calculations, soil geogrid reinforcement analysis, and municipal building permits (IBC 1807.2 / AS 4678). Surcharge loads (slopes, driveways, or structures above the wall) trigger engineering at any height.
  • Concrete Slabs & Footings: Calculations apply strictly to residential grade-supported slabs and gravity footings. Suspended structural designs, elevated decks, and commercial foundation footings require certified engineering drawings.
  • Timber & Carpentry: Structural ledger connections, multi-story post sizing, and beam spans must be verified against local building codes (IRC 2021 / AS 1684 / Eurocode 5).

2. Vehicle Payload & Hauling Safety

Hauling bulk aggregates, gravel, or heavy concrete bags carries severe risks of axle failure, snapped leaf springs, and tire blowouts:

General physics estimate only. Payload ratings vary by vehicle trim, cab configuration, bed length, and suspension packages. Always check your specific driver-door tire and loading placard (Gross Vehicle Weight Rating [GVWR] minus vehicle curb weight) before hauling aggregate or bagged concrete.

3. Subgrade Compaction & Material Variances

Quarry aggregates vary by ±15% based on moisture content (damp vs. bone-dry stone). Crushed road base consolidates by 15% to 20% under mechanical plate compactors. Excavation depth irregularities and formwork deflection can increase concrete requirements by 10% or more. Always order an appropriate waste contingency.

View Full Construction Disclaimer Page →